Water Pipe Sizer SE 1.3 [free]

ソフトウェア

Thank you for using Water Pipe Sizer SE, the standard edition of Water Pipe Sizer for Android!
Water Pipe Sizer SE, a clean water pipe sizing application program for android devices is a handy tool for civil engineers, designers, and other engineering professionals who
are involved in clean water networks design. The app features quick pipe sizing and quick calculations for flow velocity and pipe head loss due to friction. It is intended for
single pipe analysis or one pipe at a time for series of pipes and thus, may serve as a tool for design reviewers when verifying pipe sizes in hydraulic models. Pipe size
selection is based on built in catalog for various pipe materials compliant to certain standards.
There are currently two versions of Water Pipe Sizer; a lite version and a Standard Edition (SE). The lite version is offered with minimal relevant features for free while the
standard edition is also offered free on Google Play. The lite version features basic hydraulic calculations for pipe sizing, actual fluid velocity, specific head loss, and head
loss gradient. The SE version offers additional features for pipe size optimization and a spreadsheet for population/consumer based design flow calculations for water network
trunk lines.
Design Criteria:
In the “Demand Calculations” screen, a conservative Average Daily per capita potable water demand of 250 liters per day for regions with arid climate is the default value. The
rest of the sample data for typical average daily demand per consumer class are also shown to provide basic calculation data for the user. The user shall change the sample
typical average daily demand according to local requirements.
Max Daily Demand is 1.8 x average daily demand, and Peak Hourly Demand is 1.5 x Max Daily Demand. The Design Demand is the sum of 64 liters per second fire flow and the Max
Daily Demand or the Peak Hourly Demand whichever is higher, plus the peak process water demand if applicable. Fire flow is assumed to be 64 liters per second (500 GPM) for
residential area external fire water requirement. Refer to AWWA, NFPA and IFC standards for more information.
Algorithms used in Water Pipe Sizer SE are based on principles of hydraulics for pressure pipes. Pipe sizing calculation is based on the discharge/continuity formula:
Eq. 1 Q = AV
Where: Q = Flow (m³/sec)
A = πD²/4 for circular pipe (m²)
V = Velocity (m/s)
D = Pipe Diameter (mm)
And:
Eq. 2 D = 1000 * sqrt(4Q / (πV)) (mm)
Head loss calculation is based on Hazen-Williams friction loss equation:
Eq. 3 Hf = 10.7L(Q/C)^(1.85 )/D^(4.87)
Where: Hf = friction loss in meters
L = pipe length in meters
C = Hazen-Williams friction loss coefficient
D = diameter of pipe in millimeters
Pipe sizes are based on standard specifications for the following materials: Ductile Iron (DI), IS0 2531, BSEN 545 & 598; Reinforced Thermosetting Resin / Fiberglass (RTR,
GRP, GRE, FRP), AWWA C950-01; High Density Polyethylene (HDPE), SDR11, PN16, PE100; uPVC, PN16, Class 5, EN12162, ASTM1784. Inside pipe diameter or nominal bore for other
standards may differ and not included in the built-in catalogues in this application. However, the user can still use the app to determine the required internal diameter for
other pipes of different pressure classes and refer to pipe corresponding catalogues for standard nominal pipe diameter selection.
Disclaimer:
Potable water, irrigation and fire water requirements vary according to geographic location, local standards and regulations. The user is assumed to be skilled in calculating
design demands, flow in pipes and pressure loss based on local design criteria mandated by local authorities. The user is responsible in checking the accuracy of his/her own
work and solely responsible for the results obtained from using this application.

バージョン履歴

Free Download ダウンロードする二次元コード
  • ソフトウェアの名称: Water Pipe Sizer SE
  • ソフトウェアカテゴリ: 仕事効率化
  • APK名: appinventor.ai_arnulfo_bataller.WaterPipeSizerSE_v1
  • 最新バージョン: 1.3
  • サポートROM: 1.6 以上
  • ファイルサイズ : 11.71 MB
  • 更新した: 2022-09-28